Electrical equipment Technical data Generator Rated power, V/A 4G9 engine - 2/85.12/100* 4G1 engine - 12/90 diesel engine without air conditioning system - 12/80 diesel engine with air...
Charging system Pic. 19.1. Diagram of the 4G9 engine charging system Pic. 19.2. Diagram of the 4G1 engine charging system The charging system uses the power from the alternator to keep...
Checking the output current of the generator Pic. 19.4. Connecting wires and devices to the generator when checking the output current of the 4G9 engine generator Pic. 19.5. Connecting wires and devices to the...
Generator Relay Test 1. Remove the generator relay from the relay box located in the engine compartment (pic. 19.6). Pic. 19.6. Location of generator relay and relay contacts 2. Connect the...
Gasoline engine generator Removing On the 4G9 engine, remove the top engine cover. Remove the lower engine mudguard. Disconnect the wire from the negative battery terminal. Loosen and remove the...
Generator repair 4G9 gasoline engine generator repair Disassembly Secure the generator in a vise. Remove the four tie bolts, insert the blade of two flat screwdrivers between the front...
Accumulator battery A battery is a device for storing energy in chemical form, which can later be used as electricity. Lubricate the terminals with acid-free Vaseline and anti-corrosion...
Checking the level and density of the electrolyte The electrolyte level must be between the UPPER LEVEL marks (Top level) and LOWER LEVEL (Lower level), marked on the battery case. Use a hydrometer and a thermometer to...
Charging the battery When charging a battery installed on a car, first disconnect the negative wire from its terminals, and then the positive one, so that there is no damage to electrical...
Launch system The starting system includes a battery, a starter, a traction relay, an ignition switch, an interlock switch (only on vehicles with automatic transmission) and wires....
Checking and replacing starter elements Checking and adjusting the axial clearance of the gear Disconnect the wire of the excitation coil from the terminal M of the traction relay. Connect the battery...