Pic. 17.7. Using the special tool MB990900 or MB991164 (1) for adjusting the installation position of the door
1. If the gap between the door and the body is uneven, stick the protective tape on the door contact surface and around the door hinge on the body. Then loosen the bolts securing the door hinge to the body and use the special tool MB990900 or MB991164 to adjust the gap between the door and the body (pic. 17.7).
2. If the closed door is not flush with the surface of the body, use a special tool to adjust its position after loosening the bolts securing the door hinges to the body.
3. If it is difficult to open and close the door, adjust the position of the lock and latch by adjusting the position of the latch.