Checking the oil cooler bypass valve
Make sure the valve moves smoothly without sticking.
Check that the distance «L» at normal temperature (20°C) and humidity corresponds to the nominal value.
Distance «L» (at 20°C): 34.5 mm.
Check that the valve travel «L» increases above the nominal value after the valve is immersed in oil heated to a temperature of 97-103°C.
Distance «L» (at 97–103°C): 40 mm or more.
Install the bottom guards.
Removing the oil cooler
Remove the lower protective covers,
Drain the engine oil.
Drain the coolant.
Remove expansion tank assembly.
Remove the front bumper assembly.
Oil cooler installation
Installation of details is made in an order, the return to removal.
Install the front bumper assembly.
Install expansion tank assembly.
Fill with coolant.
Fill with engine oil.
Install the bottom guards.