2. Attach a vacuum pump to the valve (pic. 6.15).
Pic. 6.15. Checking the tightness of the exhaust gas recirculation valve
3. Create a vacuum of 67 kPa and check for leaks.
4. Apply air from the exhaust gas recirculation channel and check the following condition of the system:
Vacuum | Air permeability |
5.3 kPa or below | No air leakage |
27 kPa or higher | Air leak |
5. When installing the valve of the recirculation system, install a new gasket and tighten it to a torque of 22 Nm.